KPC Inc. · Korea Power Challenge

Industrial LED lighting built for demanding project environments.

KPC Inc. delivers high-power LED floodlights and explosion-proof lighting solutions for shipyards, ports, industrial yards, power plants, factories and large outdoor projects — manufactured in Daejeon, Republic of Korea.

Origin
South Korea
Focus
Heavy Industry
Supply
Project Export
Reference SiteREF · 001
Site
Shipyard · High Mast
Mounting H.
35 m
Model
KPC-1000N
Beam · IP
30° · IP66
Output
110,930 lm
Region
Republic of Korea
Live Project DataActive
Scroll
Max output range
0W
KPC-1000N lumen
0 lm
Ingress protection
IP0
Step project workflow
0
Approach

Built for project conditions, not just catalog sales.

KPC works directly with EPC contractors, distributors and plant owners — matching the right fixture to the actual site requirement, then supporting the project through to delivery and after-sales.

  • 01
    Site-driven product selection
    Fixture choice driven by site type, mounting height and ambient environment — not by catalog defaults.
  • 02
    Photometric review
    Beam angle and wattage matched to required illuminance and uniformity targets.
  • 03
    High mast & outdoor zones
    Configuration support for masts, poles and large outdoor industrial yards.
  • 04
    Harsh-environment construction
    IP66 housings and Ex d IIC product options for chemical, marine and dusty environments.
  • 05
    Export documentation
    Technical data sheets, photometric files (.ies) and packing documents prepared per project.
  • 06
    Direct technical communication
    English communication with overseas project teams, distributors and end-users.
KPC-N Series industrial LED floodlight close-up
Fig. 01 · KPC-N Series
Multi-fin aluminum heat sink
Toughened glass · IP66
KPC-Ex explosion-proof fixture
KPC-Ex
Explosion-Proof
100 – 200 W · Ex d IIC
High mast yard lighting installation
KPC-HM
High Mast / Yard
Site-engineered assemblies
Flagship Series

KPC-N Series
High-Power LED Floodlights

The core KPC industrial floodlight range. Six wattage steps from 150 W to 1000 W, with interchangeable beam optics for shipyard, port, steel mill and high mast applications.

Model
Power
Lumen ≥
lm/W ≥
KPC-150N
150 W
16,342
115
KPC-270N
270 W
31,502
120
KPC-400N
400 W
45,250
113
KPC-600N
600 W
74,440
127
KPC-800N
800 W
79,295
103
KPC-1000N
1000 W
110,930
109
Beam: 15° / 30° / 60° / 90°· IP66· CCT 4000 / 5700 K· AC 100–277 V

Figures shown are reference values. Final lumen output and efficacy depend on optical configuration and order specification. Photometric data (.ies) issued with quotation.

Application Reference

Model selection by mounting height & site type.

Reference table for initial product selection. Final fixture choice is confirmed after site review and photometric study.

ModelPowerLumen ≥lm/W ≥Beam OptionsTypical Mounting H.
KPC-150N150 W16,34211515° / 30° / 60° / 90°8 – 15 m
KPC-270N270 W31,50212015° / 30° / 60° / 90°12 – 20 m
KPC-400N400 W45,25011315° / 30° / 60° / 90°15 – 25 m
KPC-600N600 W74,44012715° / 30° / 60° / 90°20 – 35 m
KPC-800N800 W79,29510315° / 30° / 60° / 90°25 – 40 m
KPC-1000N1000 W110,93010915° / 30° / 60° / 90°30 – 45 m
KPC-Ex Series
Explosion-Proof LED Lighting
Ex d IIC · IP66
ModelPowerLumen ≥lm/W ≥
KPC-100Ex100 W12,000120
KPC-150Ex150 W18,000120
KPC-200Ex200 W24,000120
Chapter 02 — Where it operates

From dry docks to container terminals,
where industry never sleeps.

24 / 7 outdoor industrial operation
Project Supply Process

A structured workflow from inquiry to after-sales.

The same workflow applied to every project — for industrial buyers, EPC contractors and distributors, regardless of project size.

  1. Step 01
    Site Requirement Review
    Site type, mounting height, target lux, ambient conditions.
  2. Step 02
    Product & Wattage Selection
    Floodlight or Ex-proof model, wattage and beam angle.
  3. Step 03
    Technical Data & Quotation
    Spec sheets, photometric data and project quotation.
  4. Step 04
    Sample / Spec Confirmation
    Sample shipment or written specification confirmation.
  5. Step 05
    Production & Quality Check
    In-house assembly and pre-shipment inspection.
  6. Step 06
    Export Packing & Delivery
    Export packing, shipping documents and delivery support.
  7. Step 07
    After-Sales Technical Support
    Technical communication for installation and operation.
Chapter 03 — Field-proven

Engineered for heat, dust,
vibration, salt and shock.

Selected reference projects across heavy industry — supplied directly from Daejeon under the same project workflow.

IP66
Ingress rating
Ex d IIC
Hazardous-area
−30 / +55 °C
Operating temp.
50,000 h
L70 lifetime
Industrial Reference Experience

Lighting solutions for heavy-duty environments.

KPC has supplied industrial LED lighting for environments such as shipyards, industrial yards, ports and large outdoor facilities.

See project references
Shipyard / Dry Dock
Ref · 001
Republic of Korea

Shipyard / Dry Dock

KPC-1000N · 30° beam · 35 m mast · IP66
Challenge

Wide outdoor area requiring uniform high-lumen lighting and salt-air resistance.

KPC Solution

High-power LED floodlights mounted on existing mast structures with reduced fixture count.

Container Port
Ref · 002
Export Project

Container Port

KPC-600N · 30° / 60° mix · 30 m high mast
Challenge

Continuous container handling requiring stable wide-area illumination.

KPC Solution

Mixed beam configuration delivering uniform horizontal and vertical illuminance.

Petrochemical Facility
Ref · 003
Hazardous Zone

Petrochemical Facility

KPC-150Ex · Ex d IIC · IP66
Challenge

Classified zone requiring certified explosion-proof fixtures for process and walkway areas.

KPC Solution

Ex d IIC LED lighting replacing legacy HID with reduced maintenance frequency.

Outdoor Sports Facility
Ref · 004
Asia Project

Outdoor Sports Facility

KPC-800N · 15° narrow beam · 25 m pole
Challenge

Long-throw coverage from limited mast positions for field uniformity.

KPC Solution

Narrow-beam optics achieving target uniformity with lower energy use vs. metal halide.

— Project Inquiry

Need lighting support
for a project site?

Share your site conditions, installation height, project type and target lighting requirements. KPC can support product selection and technical quotation preparation — typically within 2–3 business days.

Inquiry Checklist
Information to include
Company / Country
Buyer, EPC, distributor
Project type
Shipyard, port, plant, etc.
Product interest
Floodlight / Ex-proof / High mast
Required wattage
e.g. 400 W / 600 W / 1000 W
Installation height
Mounting height (m)
Target illumination
Required lux level
Site conditions
Marine, dust, hazardous zone
Quantity / Timeline
Order quantity and target date