KPC Inc. · Korea Power Challenge

Industrial LED lighting built for demanding project environments.

KPC Inc. delivers high-power LED floodlights and explosion-proof lighting solutions for shipyards, ports, industrial yards, power plants, factories and large outdoor projects — manufactured in Daejeon, Republic of Korea.

Origin
South Korea
Focus
Heavy Industry
Supply
Project Export
Reference SiteREF · 001
Site
Shipyard · High Mast
Mounting H.
35 m
Model
KPC-1000N
Beam · IP
30° · IP66
Output
110,930 lm
Region
Republic of Korea
Live Project DataActive
Scroll
Max output range
0W
KPC-1000N lumen
0 lm
Ingress protection
IP0
Step project workflow
0
New ProductComing Soon

Solar-Powered Smart Guardrail Safety Light

An innovative solar-powered safety lighting solution designed for guardrails, roads, fences and smart city infrastructure — no grid wiring required.

Power source
Solar panel + rechargeable battery
Light emission
Multi-directional LED
Mounting
Clip-on clamp
Applications
Road · Guardrail · Work zone
Solar-powered smart guardrail safety light — four side rendering views
4-side product rendering
Solar guardrail safety light mounted on guardrails, fences and roadside posts
Clamp mounting and field applications
Approach

Built for project conditions, not just catalog sales.

KPC works directly with EPC contractors, distributors and plant owners — matching the right fixture to the actual site requirement, then supporting the project through to delivery and after-sales.

  • 01
    Site-driven product selection
    Fixture choice driven by site type, mounting height and ambient environment — not by catalog defaults.
  • 02
    Photometric review
    Beam angle and wattage matched to required illuminance and uniformity targets.
  • 03
    High mast & outdoor zones
    Configuration support for masts, poles and large outdoor industrial yards.
  • 04
    Harsh-environment construction
    IP66 housings and Ex d IIC product options for chemical, marine and dusty environments.
  • 05
    Export documentation
    Technical data sheets, photometric files (.ies) and packing documents prepared per project.
  • 06
    Direct technical communication
    English communication with overseas project teams, distributors and end-users.
KPC-N Series industrial LED floodlight close-up
Fig. 01 · KPC-N Series
Multi-fin aluminum heat sink
Toughened glass · IP66
KPC-Ex explosion-proof fixture
KPC-Ex
Explosion-Proof
100 – 200 W · Ex d IIC
High mast yard lighting installation
KPC-HM
High Mast / Yard
Site-engineered assemblies
Flagship Series

KPC-N Series
High-Power LED Floodlights

The core KPC industrial floodlight range. Six wattage steps from 150 W to 1000 W, with interchangeable beam optics for shipyard, port, steel mill and high mast applications.

Model
Power
Lumen ≥
lm/W ≥
KPC-150N
150 W
16,342
115
KPC-270N
270 W
31,502
120
KPC-400N
400 W
45,250
113
KPC-600N
600 W
74,440
127
KPC-800N
800 W
79,295
103
KPC-1000N
1000 W
110,930
109
Beam: 15° / 30° / 60° / 90°· IP66· CCT 4000 / 5700 K· AC 100–277 V

Figures shown are reference values. Final lumen output and efficacy depend on optical configuration and order specification. Photometric data (.ies) issued with quotation.

Application Reference

Model selection by mounting height & site type.

Reference table for initial product selection. Final fixture choice is confirmed after site review and photometric study.

ModelPowerLumen ≥lm/W ≥Beam OptionsTypical Mounting H.
KPC-150N150 W16,34211515° / 30° / 60° / 90°8 – 15 m
KPC-270N270 W31,50212015° / 30° / 60° / 90°12 – 20 m
KPC-400N400 W45,25011315° / 30° / 60° / 90°15 – 25 m
KPC-600N600 W74,44012715° / 30° / 60° / 90°20 – 35 m
KPC-800N800 W79,29510315° / 30° / 60° / 90°25 – 40 m
KPC-1000N1000 W110,93010915° / 30° / 60° / 90°30 – 45 m
KPC-Ex Series
Explosion-Proof LED Lighting
Ex d IIC · IP66
ModelPowerLumen ≥lm/W ≥
KPC-100Ex100 W12,000120
KPC-150Ex150 W18,000120
KPC-200Ex200 W24,000120
Chapter 02 — Where it operates

From dry docks to container terminals,
where industry never sleeps.

24 / 7 outdoor industrial operation
Project Supply Process

A structured workflow from inquiry to after-sales.

The same workflow applied to every project — for industrial buyers, EPC contractors and distributors, regardless of project size.

  1. Step 01
    Site Requirement Review
    Site type, mounting height, target lux, ambient conditions.
  2. Step 02
    Product & Wattage Selection
    Floodlight or Ex-proof model, wattage and beam angle.
  3. Step 03
    Technical Data & Quotation
    Spec sheets, photometric data and project quotation.
  4. Step 04
    Sample / Spec Confirmation
    Sample shipment or written specification confirmation.
  5. Step 05
    Production & Quality Check
    In-house assembly and pre-shipment inspection.
  6. Step 06
    Export Packing & Delivery
    Export packing, shipping documents and delivery support.
  7. Step 07
    After-Sales Technical Support
    Technical communication for installation and operation.
Chapter 03 — Field-proven

Engineered for heat, dust,
vibration, salt and shock.

Selected reference projects across heavy industry — supplied directly from Daejeon under the same project workflow.

IP66
Ingress rating
Ex d IIC
Hazardous-area
−30 / +55 °C
Operating temp.
50,000 h
L70 lifetime
Industrial Reference Experience

Lighting solutions for heavy-duty environments.

KPC has supplied industrial LED lighting for environments such as shipyards, industrial yards, ports and large outdoor facilities.

See project references
Shipyard / Dry Dock
Ref · 001
Republic of Korea

Shipyard / Dry Dock

KPC-1000N · 30° beam · 35 m mast · IP66
Challenge

Wide outdoor area requiring uniform high-lumen lighting and salt-air resistance.

KPC Solution

High-power LED floodlights mounted on existing mast structures with reduced fixture count.

Container Port
Ref · 002
Export Project

Container Port

KPC-600N · 30° / 60° mix · 30 m high mast
Challenge

Continuous container handling requiring stable wide-area illumination.

KPC Solution

Mixed beam configuration delivering uniform horizontal and vertical illuminance.

Petrochemical Facility
Ref · 003
Hazardous Zone

Petrochemical Facility

KPC-150Ex · Ex d IIC · IP66
Challenge

Classified zone requiring certified explosion-proof fixtures for process and walkway areas.

KPC Solution

Ex d IIC LED lighting replacing legacy HID with reduced maintenance frequency.

Outdoor Sports Facility
Ref · 004
Asia Project

Outdoor Sports Facility

KPC-800N · 15° narrow beam · 25 m pole
Challenge

Long-throw coverage from limited mast positions for field uniformity.

KPC Solution

Narrow-beam optics achieving target uniformity with lower energy use vs. metal halide.

— Project Inquiry

Need lighting support
for a project site?

Share your site conditions, installation height, project type and target lighting requirements. KPC can support product selection and technical quotation preparation — typically within 2–3 business days.

Inquiry Checklist
Information to include
Company / Country
Buyer, EPC, distributor
Project type
Shipyard, port, plant, etc.
Product interest
Floodlight / Ex-proof / High mast
Required wattage
e.g. 400 W / 600 W / 1000 W
Installation height
Mounting height (m)
Target illumination
Required lux level
Site conditions
Marine, dust, hazardous zone
Quantity / Timeline
Order quantity and target date